Fatal Error Alarm

acBoardFatalError

Alarm

acBoardFatalError

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.1

Description

The alarm is sent when a fatal problem occurs in the device's internal logic, and the device automatically restarts to resolve this problem, bringing it back to service.

Default Severity

Critical

Source Varbind Text

Board#1

Event Type

equipmentAlarm

Probable Cause

underlyingResourceUnavailable (56)

Severity

Condition

Text

Corrective Action

Critical

Fatal problem in internal logic occurs.

"Board Fatal Error: A run-time specific string describing the fatal error"

The device automatically restarts to resolve the internal logic problem.

Send the syslog file and the Debug file (with the Core Dump file, if enabled) to AudioCodes support to diagnose the problem.

Cleared (although 'Clear' trap not sent)

After restart.

-